fractional-order proportional integrator based Search Results


90
IEEE Access hybrid fuzzy poisson fractional order proportional integral derivative controller
Hybrid Fuzzy Poisson Fractional Order Proportional Integral Derivative Controller, supplied by IEEE Access, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/hybrid fuzzy poisson fractional order proportional integral derivative controller/product/IEEE Access
Average 90 stars, based on 1 article reviews
hybrid fuzzy poisson fractional order proportional integral derivative controller - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

90
Statcom Co Ltd fractional-order proportional integrator based
Parameters of PI and <t> FOPI </t> controllers
Fractional Order Proportional Integrator Based, supplied by Statcom Co Ltd, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fractional-order proportional integrator based/product/Statcom Co Ltd
Average 90 stars, based on 1 article reviews
fractional-order proportional integrator based - by Bioz Stars, 2026-04
90/100 stars
  Buy from Supplier

Image Search Results


Parameters of PI and  FOPI  controllers

Journal: SpringerPlus

Article Title: Fractional-order PI based STATCOM and UPFC controller to diminish subsynchronous resonance

doi: 10.1186/s40064-016-2727-y

Figure Lengend Snippet: Parameters of PI and FOPI controllers

Article Snippet: In this paper a Fractional-order proportional integrator (FOPI) based STATCOM and UPFC is used for mitigating the subsynchronous oscillations in turbine-generator shaft due to SSR.

Techniques:

Simulated Torque and Stress between LPB-Generator of IEEE first benchmark model with FOPI based STATCOM and PI based UPFC controllers. a With FOPI based STATCOM controller and b With PI based UPFC controller

Journal: SpringerPlus

Article Title: Fractional-order PI based STATCOM and UPFC controller to diminish subsynchronous resonance

doi: 10.1186/s40064-016-2727-y

Figure Lengend Snippet: Simulated Torque and Stress between LPB-Generator of IEEE first benchmark model with FOPI based STATCOM and PI based UPFC controllers. a With FOPI based STATCOM controller and b With PI based UPFC controller

Article Snippet: In this paper a Fractional-order proportional integrator (FOPI) based STATCOM and UPFC is used for mitigating the subsynchronous oscillations in turbine-generator shaft due to SSR.

Techniques:

Change in Electro-Magnetic torque and change in Rotor speed of IEEE first benchmark model with FOPI based STATCOM and PI based UPFC controllers. a With FOPI based STATCOM controller and b With PI based UPFC controller

Journal: SpringerPlus

Article Title: Fractional-order PI based STATCOM and UPFC controller to diminish subsynchronous resonance

doi: 10.1186/s40064-016-2727-y

Figure Lengend Snippet: Change in Electro-Magnetic torque and change in Rotor speed of IEEE first benchmark model with FOPI based STATCOM and PI based UPFC controllers. a With FOPI based STATCOM controller and b With PI based UPFC controller

Article Snippet: In this paper a Fractional-order proportional integrator (FOPI) based STATCOM and UPFC is used for mitigating the subsynchronous oscillations in turbine-generator shaft due to SSR.

Techniques:

Change in Electro-Magnetic torque and change in Rotor speed of IEEE first benchmark model with FOPI based UPFC controller. With FOPI based UPFC controller

Journal: SpringerPlus

Article Title: Fractional-order PI based STATCOM and UPFC controller to diminish subsynchronous resonance

doi: 10.1186/s40064-016-2727-y

Figure Lengend Snippet: Change in Electro-Magnetic torque and change in Rotor speed of IEEE first benchmark model with FOPI based UPFC controller. With FOPI based UPFC controller

Article Snippet: In this paper a Fractional-order proportional integrator (FOPI) based STATCOM and UPFC is used for mitigating the subsynchronous oscillations in turbine-generator shaft due to SSR.

Techniques:

Injected currents of PI and FOPI based STATCOM controllers during three-phase fault to mitigate the SSR. a Current injected by PI based STATCOM controller and b Current injected by FOPI based STATCOM controller

Journal: SpringerPlus

Article Title: Fractional-order PI based STATCOM and UPFC controller to diminish subsynchronous resonance

doi: 10.1186/s40064-016-2727-y

Figure Lengend Snippet: Injected currents of PI and FOPI based STATCOM controllers during three-phase fault to mitigate the SSR. a Current injected by PI based STATCOM controller and b Current injected by FOPI based STATCOM controller

Article Snippet: In this paper a Fractional-order proportional integrator (FOPI) based STATCOM and UPFC is used for mitigating the subsynchronous oscillations in turbine-generator shaft due to SSR.

Techniques: Injection

Current and voltage injected by PI and FOPI based UPFC controllers during three-phase fault to mitigate the SSR. a Shunt current and series voltage injected by PI based UPFC controller and b Shunt current and series voltage injected by FOPI based UPFC controller

Journal: SpringerPlus

Article Title: Fractional-order PI based STATCOM and UPFC controller to diminish subsynchronous resonance

doi: 10.1186/s40064-016-2727-y

Figure Lengend Snippet: Current and voltage injected by PI and FOPI based UPFC controllers during three-phase fault to mitigate the SSR. a Shunt current and series voltage injected by PI based UPFC controller and b Shunt current and series voltage injected by FOPI based UPFC controller

Article Snippet: In this paper a Fractional-order proportional integrator (FOPI) based STATCOM and UPFC is used for mitigating the subsynchronous oscillations in turbine-generator shaft due to SSR.

Techniques: Injection

Comparison of different performance indexes of IEEE first benchmark model with PI and with  FOPI  based STATCOM and UPFC controllers

Journal: SpringerPlus

Article Title: Fractional-order PI based STATCOM and UPFC controller to diminish subsynchronous resonance

doi: 10.1186/s40064-016-2727-y

Figure Lengend Snippet: Comparison of different performance indexes of IEEE first benchmark model with PI and with FOPI based STATCOM and UPFC controllers

Article Snippet: In this paper a Fractional-order proportional integrator (FOPI) based STATCOM and UPFC is used for mitigating the subsynchronous oscillations in turbine-generator shaft due to SSR.

Techniques: Comparison